Electric Strike Installation

Last updated: April 26, 2026

Commercial electric strike installation for Treasure Coast access control systems. HES 1006, Von Duprin 6000 series, Folger Adam 310, Adams Rite 7140, and full electric strike lineup with REX and DPS integration.

HES 1006Von Duprin 6000Fail-safe/secure
TL;DR - Quick Answer

Treasure Coast Locksmith provides electric strike installation services in Port St. Lucie, Stuart, Fort Pierce, Vero Beach, Jensen Beach, and across the Treasure Coast. Call (772) 758-1322 for mobile service. Electric strikes allow access control systems to release door latches electronically. Common models: HES 1006 for hollow metal frames, Von Duprin 6000 series for exit devices, Folger Adam 310 for high-security, Adams Rite 7140 for aluminum storefronts.

Florida Licensed
Fully Insured
Over 500 reviews - 5.0 Stars
20+ Years Experience
Mobile Service - We Come to You

Electric strikes are how most access control systems release door latches. The strike replaces the standard strike plate in the door frame and includes an electric mechanism that releases the latch when signaled by the access panel. Card swipe or button press sends voltage to the strike, which releases the latch and allows the door to open.

Electric strikes come in two configurations: fail-safe (unlocks on power loss for emergency egress) and fail-secure (stays locked on power loss for security). The choice depends on door function and code requirements. Emergency exit doors typically require fail-safe to ensure egress during power failures.

Treasure Coast Locksmith installs electric strikes for commercial access control systems across Port St. Lucie, Stuart, Vero Beach, and the Treasure Coast. We work with HES, Von Duprin, Folger Adam, Adams Rite, and other commercial strike brands.

Integration includes REX (request to exit) and DPS (door position switch) connections to access panels.

HES electric strike installed
HES 1006 electric strike installed in hollow metal frame.

Electric strike specialty

  • HES 1006 expertise - the commercial workhorse strike.
  • Von Duprin 6000 series - integrates with exit devices.
  • Folger Adam 310 - high-security applications.
  • Adams Rite 7140 - aluminum storefront strike.
  • Fail-safe/secure config - matched to egress requirements.
  • REX and DPS integration - access panel connection.
  • Fire door compliance - UL-listed fire rated strikes.
  • Frame preparation - proper mortising and fitting.

Common electric strike scenarios

Real electric strike installation situations.

Typical calls

  • Port St. Lucie office with HES 1006 install for new access control system.
  • Stuart retail with Adams Rite 7140 on aluminum storefront entry.
  • Vero Beach medical with Von Duprin 6000 series for exit device integration.
  • Fort Pierce warehouse with high-security Folger Adam 310 install.
  • Jensen Beach bank with fail-secure strike for after-hours lockdown.
  • Tradition apartment complex with strike upgrade for key fob system.
  • Palm City restaurant with fail-safe strike for kitchen fire exit.
  • Treasure Coast school with multi-door strike rollout for access control.
Electric strike wiring to access panel
Electric strike wiring to access control panel with REX and DPS.

Electric strike types, configurations, and specifications

Electric strikes are categorized by frame type, fail configuration, voltage, and application. Choosing the right strike matters because wrong specification creates security or compliance issues.

HES Electric Strikes: HES (Hanchett Entry Systems) dominates the commercial electric strike market. 1006 series is the workhorse for hollow metal frames - available in multiple keeper configurations, voltages, and fail options. 9000 series for wood frames.

5000 series for aluminum storefronts. HES is part of Assa Abloy family.

Von Duprin 6000 Series: Electric strikes designed to integrate with Von Duprin exit devices. Used when exit device must be locked from outside via access control while maintaining free egress. The strike works with the latch from the exit device, providing access control on the entry side.

Folger Adam 310: High-security electric strike with heavy-duty construction and tamper resistance. Used in banks, jails, evidence rooms, and high-security commercial applications. Higher cost but much more secure than standard commercial strikes.

Adams Rite 7140/7170: Electric strikes specifically designed for Adams Rite MS1850S storefront deadlocks. Used on aluminum storefront doors in retail, office lobbies, and commercial entrances. Compatible with standard storefront preparation.

Fail-Safe vs Fail-Secure: Fail-safe strikes unlock when power is removed. Used for doors that must allow egress during power failures - typical for emergency exits, life safety applications, and any door where fire safety egress is required. Fail-secure strikes stay locked when power is removed.

Used for doors where security takes priority over convenience during power failures - typical for secured areas where backup power is provided.

Code Requirements: NFPA 101 life safety code affects electric strike selection. Most egress doors require fail-safe configuration unless specifically exempted. Fire marshal and local code authority determine requirements for specific doors.

See NFPA 101 for life safety code details.

Voltage Options: 12 VDC and 24 VDC are the most common commercial voltages. 12 VDC is more common for small systems. 24 VDC is standard for larger enterprise systems.

Verify strike voltage matches access panel power supply. Wrong voltage burns out the strike coil.

REX and DPS Integration: REX (Request to Exit) is a motion sensor or button that tells the access panel someone is leaving, preventing false alarm. DPS (Door Position Switch) tells the panel whether the door is open or closed for held-open detection and door-forced-open alerts. Both connect to the access panel at the same time as the strike wiring.

Frame Preparation: Electric strikes require specific cutouts in the door frame. Retrofits into existing frames may require welding, grinding, or filling depending on existing prep. New construction specifications should include strike cutout details on door schedule.

Adams Rite electric strike on storefront
Adams Rite 7140 electric strike on aluminum storefront door.

Electric strike installation process

Application assessment

Call (772) 758-1322.

Discuss door type, access panel, egress requirements.

Specification

Choose strike model, voltage, fail configuration, and accessories.

Installation

Mortise frame, install strike, run wiring to access panel.

Integration and testing

Connect to panel, test fail mode, verify REX and DPS operation.

Electric strike tips

  • Always verify fail configuration matches egress requirements.
  • Match strike voltage to access panel power supply.
  • Test REX and DPS during installation.
  • Use UL-listed strikes on fire-rated doors.
  • Document strike model and voltage in as-built records.
  • Plan for backup power on critical doors.

Electric strike installation FAQs

Common questions from Treasure Coast businesses and access control integrators.

How much does electric strike installation cost?

Standard HES 1006 installed: $595-$995 including wiring to panel. Aluminum storefront strike (Adams Rite): $495-$895. High-security Folger Adam: $895-$1,495.

Retrofit into existing frames costs more than new construction. Free quote.

What's the difference between fail-safe and fail-secure?

Fail-safe strikes unlock when power is removed - required for most egress doors to ensure emergency exit during power failures. Fail-secure stays locked when power is removed - used for security-priority doors with backup power. Code and application determine which to use.

Can you install on an existing door?

Yes. Retrofit installation on existing hollow metal, wood, or aluminum storefront frames. May require frame preparation - mortising, welding, or strike plate modification.

Evaluation during site visit.

Do you integrate with my access control?

Yes. HES, Von Duprin, Folger Adam, and Adams Rite strikes integrate with all major access control panels. HID, Honeywell, Software House, Brivo, Openpath, and other commercial systems supported.

Wiring includes strike, REX, and DPS connections.

What about fire doors?

UL-listed electric strikes available for fire-rated doors. HES 1006 has UL-rated models for 90-minute, 3-hour fire ratings. Must be specifically rated for fire application - non-rated strikes invalidate fire door rating.

Can you install on aluminum storefronts?

Yes. Adams Rite 7140/7170 electric strikes designed specifically for aluminum storefront doors. Compatible with standard MS1850S deadlock preparation.

Common installation for retail, office lobby, and commercial entry doors.

What voltage do I need?

Depends on access panel power supply. 12 VDC common for small systems, 24 VDC for larger enterprise. Must match panel voltage exactly - wrong voltage burns out strike coil.

We verify during specification phase.

How do strikes work with exit devices?

Von Duprin 6000 series electric strikes integrate with Von Duprin exit devices. Exit device provides free egress from inside, electric strike provides access control on outside. Combined solution common for assembly occupancy buildings.

Can you handle high-security applications?

Yes. Folger Adam 310 and similar heavy-duty electric strikes for banks, evidence rooms, and high-security commercial applications. Tamper-resistant construction and heavy-duty keepers.

Do you install REX and DPS?

Yes. REX (Request to Exit) motion sensor or button and DPS (Door Position Switch) included in scope when installing electric strikes for access control. REX prevents false exit alarms, DPS detects held-open and forced-open conditions.

What about weatherproof exterior applications?

Weatherproof electric strikes available for exterior doors. IP-rated construction for salt air and humidity. Important for Florida coastal installations where standard strikes corrode quickly.

Can you upgrade existing magnetic locks to electric strikes?

Yes, often recommended. Electric strikes are usually more reliable than mag locks for commercial access and don't have the same code compliance issues around REX/motion sensors. Evaluation during assessment.

Pricing Guide

ServicePrice Range
Commercial rekey (first door)$95 - $195
Commercial rekey (additional)$55 - $85 each
Master key system design$295 - $795+
Panic bar installation$395 - $895
Door closer replacement$195 - $495
Access control (per door)$495 - $1,495
Commercial lockout$95 - $195

Prices may vary depending on job difficulty, materials used, and current market prices. A phone quote is provided before dispatch - no hidden fees.

What Our Customers Say

Over 500 Google reviews - 5.0 star average

"Positively great service. Daniel arrived, installed my keyless entry system, and stayed until I was comfortable using the new entry. I highly recommend!!"

- Sandy Carna

"Daniel from Treasure Coast Locksmith arrived within 1 hour of my call and successfully opened my front door within minutes. He was professional, kind and got the job done!"

- Joann Sandler

"Eddie came out 7:30 at night to my home and made me a key fob for my car. He was very polite and punctual. I think it took him 15 minutes the most and was half the price of the dealership."

- Joey Dee

"These guys really saved the day!! Locked out of my car on a long trip. Eddie and team were responsive, timely and got the job done quickly. Highly recommend their services."

- Frank Antonucci

Read all Over 500 reviews on Google →

Related Guides

Choosing a Commercial Locksmith → How Master Key Systems Work → Access Control for Small Business →

Request a Free Quote

For non-urgent inquiries. Need help now? Call (772) 758-1322

Electric strike installation Treasure Coast

Call (772) 758-1322 for commercial electric strike installation and access control integration across Port St. Lucie, Stuart, Vero Beach, and the Treasure Coast.

Call (772) 758-1322